Single Door Disconnect Enclosures - NEMA 4, 4X
Selection Guide |
<< Product Information << Disconnect Enclosures <<
|
| |
| Hammond Series |
1447S |
EN4DCS all versions |
| ABB Controls |
Disconnect
Switch
|
Flange operated switch (fusible or non-fusible) |
| Shaft: 8-12” dp enclosures, use DSFHS-12; 16” dp enclosures, use DSFHS-17 |
| Handle: DSFHN-HS4 |
Handle: n/a |
| Door Hardware: n/a |
Circuit
Breaker |
Circuit breaker: ABB |
| Operating Mechanism: see ABB chart |
| Shaft: 8-12” dp enclosures, use K7FHD-S12; 16” dp enclosures, use K7FHD-S17 |
| Handle: K7FHD-HS4 |
Handle: n/a |
| Door Hardware: n/a |
 |
| Allen Bradley |
1494V Flange Disconnect
Switch |
Disconnect switch and operating mechanism: Bulletin 1494V |
| Handle: Bulletin 1494V-W1 |
Handle: n/a |
Connecting rod: 8-10” dp enclosures, use 1494V-RA1; 12-16” dp enclosures,
use 1494V-RA2 |
| (except for Hammond part # 1447S46L12, use 1494V-RB2 (2)) |
| Trailer fuse block kit (if required): Bulletin 1494V |
| Fuse kit (if required) |
| Line and load connectors (if required) |
| Door Hardware: n/a |
| 1494V Flange Circuit Breaker |
Circuit breaker: C-H Westinghouse |
| Operating mechanism: Bulletin 1494V |
| Handle: Bulletin 1494V-W11 |
Handle: n/a |
Connecting rod: 8-10” dp enclosures, use 1494V-RA1; 12-16” dp enclosures,
use 1494V-RA2 |
| Door Hardware: n/a |
 |
| Cutler Hammer |
Type C361 Disconnect
Switch |
Disconnect switch and operating mechanism |
| Handle: C361-H2 or H4 |
Handle: n/a |
| Door Hardware: n/a |
Type C371
Circuit Breaker |
Circuit breaker: C-H Westinghouse |
| Operating mechanism |
| Handle: 150 amp, use C371H2 or H4; 250-600 amp, use C371H6 or H8 |
Handle: n/a |
| Door Hardware: n/a |
| C-H Westinghouse Circuit Breaker w/FlexShaft |
Circuit breaker |
| Complete Flex-Shaft handle mechanism |
| Door Hardware: n/a |
 |
| General Electric |
Type STDA
Flange
Disconnect
Switch |
Disconnect switch Type QMR or QMW |
| Handle: STDA1X |
Handle: n/a |
| Fuse kit (if required) |
| Variable depth operating mechanism |
| Door Hardware: n/a |
Type STDA
Flange
Circuit
Breaker |
Circuit breaker |
| Handle: STDA1X |
Handle: n/a |
| Variable depth operating mechanism |
| Door Hardware: n/a |
| Circuit Breaker w/SpectraFlex |
Circuit breaker |
| Flange Mt. Handle: 150-600 amp, use STDA1X; SK1200, use STDA3X |
Handle: n/a |
| Breaker mounted mechanism. |
| Operating cable |
| Door Hardware: n/a |
 |
| I-T-E Siemens |
Max-Flex
Flange
Disconnect
Switch |
Disconnect switch: MCS |
| Fuse Kit (if required) |
| Handle: Flange mount FHOHS4 |
Handle: n/a |
| Switch operator mechanism |
| Operating cable (standard 36.0”) |
| Door Hardware: n/a |
| Max-Flex Flange Circuit Breaker |
Circuit breaker |
| Pressure wire connectors |
| Handle: Flange mount FHOH4 |
Handle: n/a |
| Circuit breaker operator mechanism |
| Operating cable: Standard 36" |
| Door Hardware: n/a |
 |
| Square D |
Class 9422 Disconnect
Switch |
Disconnect switch and operating mechanism 9422 |
| Handle: 1447SN4 use A-1 or A-2; 1447SN4SS use A-2 |
Handle: n/a |
| Door Hardware: n/a |
Class 9422
Circuit
Breaker |
Circuit breaker |
| Operating mechanism: Class 9422 |
| Handle: 1447SN4 use A-1 or A-2; 1447SN4SS use A-2 |
Handle: n/a |
| Door Hardware: n/a |
Class 9422 “T” Disconnect
Switch w/ cable mechanism |
Disconnect switch and operating mechanism 9422, Type T |
| Handle: 1447SN4 use A-1 or A-2; 1447SN4SS use A-2 |
Handle: n/a |
| Cable mechanism: Class 9422 CFT_O - 3, 5, or 10 foot |
| Door Hardware: n/a |
| Circuit Breaker w/cable mechanism |
Circuit breaker: Square D |
| Handle: 1447SN4 use A-1 or A-2; 1447SN4SS use A-2 |
Handle: n/a |
| Door Hardware: n/a |
|
| |
| Space Occupied by Disconnect |
|
| Note: |
"K" |
= |
8.62 |
when |
"C" |
= |
8.00 |
| |
"K" |
= |
11.62 |
when |
"C" |
= |
12.00 |
| |
"P" |
= |
Wiring Space |
|
Disconnects will occupy space on panel shown by dimensions "K", "L" and "M".
Wiring space "P" is available when disconnect is installed in the enclosure.
*The disconnect information and space occupied tables based on data supplied by disconnect manufacturer’s bulletins. Hammond Manufacturing not responsible for dimensional accuracy.
|
|
| |
| ABB Controls
ABB Controls Disconnect Switches (Flange Mounted Operators)
|
| Fits Enclosure Depth |
ABB Switch
Number |
Amp |
|
Fuse
Class |
Space Occupied |
When
K=8.62 |
When
K=11.62 |
| 8 |
12 |
Rating |
Fuse Clip |
L |
M |
P |
P |
| • |
• |
OETL-NF30-F |
30A |
No Fuse |
— |
4.45 |
3.78 |
10.28 |
13.28 |
| • |
• |
OETL-NF60-F |
60A |
No Fuse |
— |
4.86 |
3.78 |
10.09 |
13.09 |
| • |
• |
OETL-NF100-F |
100A |
No Fuse |
— |
4.86 |
4.78 |
9.53 |
12.53 |
| • |
• |
OETL-NF175-F |
175A |
No Fuse |
— |
7.30 |
6.49 |
7.28 |
10.28 |
| • |
• |
OETL-NF200-F |
200A |
No Fuse |
— |
7.36 |
7.28 |
7.28 |
10.28 |
| • |
• |
OESA-F30J6-F |
30A |
30A-600V |
J |
4.28 |
6.58 |
8.61 |
11.61 |
| • |
• |
OESA-F60J6-F |
60A |
60A-600V |
J |
4.28 |
6.26 |
8.61 |
11.61 |
| • |
• |
OESA-F100J6-F |
100A |
100A-600V |
J ¹ |
6.54 |
7.65 |
8.17 |
11.17 |
|
|
|
200A ² |
|
|
|
|
|
|
¹ J type fuse clips are standard. If 600 V Type “T” fuse clips are desired order T type fuse adaptor kit.
² 200 A available by using non-fusible 200A switch and a trailing fuse block. (consult ABB) |
| |
| ABB Controls Circuit Breaker (Flange Mounted Operators) |
| Fits Enclosure Depth |
|
Amp |
|
Space Occupied |
When K=8.62 |
When K=11.62 |
| 8 |
12 |
ABB Mechanism |
Rating |
Fuse Type |
L |
M |
P |
P |
| • |
• |
FHD-M |
150A |
D |
6.92 |
3.94 |
9.17 |
12.17 |
| • |
• |
FHF-M |
15A-225A |
E/Q |
5.98 |
4.23 |
7.72 |
10.72 |
| • |
• |
FHF-M |
225A |
Frame |
7.44 |
4.23 |
7.72 |
10.72 |
|
• |
FHJ-M |
400A |
J |
9.71 |
5.62 |
— |
8.77 |
|
• |
FHM-M |
600A |
L |
8.28 |
11.26 |
— |
8.28 |
|
• |
FHM-M |
800A |
M |
10.11 |
11.26 |
— |
7.87 |
|
| |
| Fits Enclosure Depth |
ISOMAX Circuit
Breaker |
Amp
Rating |
Operating
Mechanism |
Fuse
Type |
Space Occupied |
When
K=4.75 |
When
K=7.09 |
| 8 |
12 |
L |
M |
P |
P |
| • |
• |
S1N100TL |
100A |
K2FHD-M |
S1 |
5.30 |
4.60 |
9.13 |
12.13 |
|
• |
S3N150TW |
150A |
K3FHD-M |
S3 |
6.67 |
5.02 |
|
11.53 |
|
• |
S3N225TW |
225A |
K3FHD-M |
S3 |
6.67 |
5.02 |
|
11.53 |
|
• |
S4N250BW |
250A |
K4FHD-M |
S4 |
8.45 |
5.02 |
|
10.00 |
|
• |
S5N400TW |
400A |
K5FHD-M |
S5 |
8.45 |
6.40 |
|
10.00 |
|
• |
S6N600TW |
600A |
K6FHD-M |
S6 |
8.33 |
10.00 |
|
9.33 |
|
• |
S6N800TW |
800A |
K6FHD-M |
S6 |
8.33 |
10.00 |
|
9.33 |
Charts reference Space Occupied by Disconnect Drawing. |
| |
Allen Bradley
Allen Bradley 1494V Disconnect Switches
| Fits Enclosure Depth |
Alan Bradley |
Amp |
|
|
Space Occupied |
When
K=8.62 |
When
K=11.62 |
| 8 |
12 |
Type Number |
Rating |
Fuse Clip |
Fuse Class |
L |
M |
P |
P |
| • |
• |
DS30 |
30A |
No Fuse |
— |
3.88 |
6.62 |
6.75 |
9.75 |
| • |
• |
DS30 |
30A |
30A-250V |
H,K,R |
5.25 |
6.62 |
6.75 |
9.75 |
| • |
• |
DS30 |
30A |
30A-600V |
H,K,R |
8.00 |
6.62 |
6.75 |
9.75 |
| • |
• |
DS30 |
30A |
30A-600V |
J |
5.25 |
6.62 |
6.75 |
9.75 |
| • |
• |
DS30 |
30A |
60A-250V |
H,K |
6.00 |
6.62 |
6.75 |
9.75 |
| • |
• |
DS30 |
30A |
60A-600V |
H,K |
8.50 |
6.62 |
6.75 |
9.75 |
| • |
• |
DS30 |
30A |
60A-600V |
J |
5.38 |
6.62 |
6.75 |
9.75 |
| • |
• |
DS60 |
60A |
No Fuse |
— |
3.88 |
6.62 |
6.62 |
9.62 |
| • |
• |
DS60 |
60A |
60A-250V |
H,K,R |
6.00 |
6.62 |
6.62 |
9.62 |
| • |
• |
DS60 |
60A |
60A-600V |
H,K,R |
8.50 |
6.62 |
6.62 |
9.62 |
| • |
• |
DS60 |
60A |
60A-600V |
J |
5.38 |
6.62 |
6.62 |
9.62 |
| • |
• |
DS60 |
60A |
30A-600V |
H,K,R |
8.00 |
6.62 |
6.62 |
9.62 |
| • |
• |
DS60 |
60A |
100A-250V |
H,K |
8.50 |
6.62 |
6.62 |
9.62 |
| • |
• |
DS60 |
60A |
100A-600V |
H,K |
10.50 |
6.62 |
6.62 |
9.62 |
| • |
• |
DS60 |
60A |
100A-600V |
J |
7.25 |
6.62 |
6.62 |
9.62 |
| • |
• |
DS100¹ |
100A |
No Fuse |
— |
3.88 |
6.62 |
6.44 |
9.62 |
| • |
• |
DS100¹ |
100A |
100A-250V |
H,K,R |
8.12 |
6.62 |
6.44 |
9.62 |
| • |
• |
DS100¹ |
100A |
100A-600V |
H,K,R |
10.12 |
6.62 |
6.44 |
9.62 |
| • |
• |
DS100¹ |
100A |
100A-600V |
J |
6.88 |
6.62 |
6.44 |
9.62 |
| • |
• |
DS100¹ |
100A |
60A-600V |
H,K,R |
10.12 |
6.62 |
6.44 |
9.62 |
| • |
• |
DS100¹ |
100A |
60A-600V |
J |
8.88 |
6.62 |
6.44 |
9.62 |
|
• |
DS200¹ |
200A |
No Fuse |
— |
4.75 |
7.88 |
— |
8.12 |
|
• |
DS200¹ |
200A |
200A-250V |
H,K,R |
10.88 |
7.88 |
— |
8.12 |
|
• |
DS200¹ |
200A |
200A-600V |
H,K,R |
13.38 |
7.88 |
— |
8.12 |
|
• |
DS200¹ |
200A |
200A-600V |
J |
9.50 |
7.88 |
— |
8.12 |
|
• |
DS200¹ |
200A |
100A-600V |
H,K,R |
12.00 |
7.88 |
— |
8.12 |
|
• |
DS200¹ |
200A |
100A-600V |
J |
8.75 |
7.88 |
— |
8.12 |
1 Series B
2 "M" dimension does not allow for auxiliary switches. |
| |
Allen Bradley 1494V Circuit Breakers
| Fits Enclosure Depth |
Allen Bradley
Type No. |
Amp Rating |
Fuse
Type |
Space
Occupied |
When
K=8.62 |
When
K=11.62 |
| 8 |
12 |
L |
M |
P |
P |
| • |
• |
M40 |
15A to 150A |
C-H Westinghouse Circuit Breakers
EHD,FD,FDB,FDC,HFD,HMCP |
5.00 |
4.50¹ |
8.12 |
|
| 11.12 |
|
• |
M50 |
70A to 250A |
C-H Westinghouse Circuit Breakers
JD,JDB,JDC,HJD,HMCP |
9.75 |
4.75¹ |
— |
|
| 10.62 |
|
• |
M60 |
100A to 400A |
C-H Westinghouse Circuit BreakersKD,KDB,DK,HKD,HMCP |
9.69 |
6.12¹ |
— |
|
| 10.50 |
1 "M" dimension does not allow for auxiliary switches.
Charts reference Space Occupied by Disconnect Drawing. |
| |
Cutler Hammer
Cutler Hammer C361 Disconnect Switches
| Fits Enclosure Depth |
Cutler Hammer |
Amp |
|
|
Space Occupied |
When
K=8.62 |
When
K=11.62 |
| 8 |
12 |
Type Number |
Rating |
Fuse Clip |
Fuse Class |
L |
M |
P |
P |
| • |
• |
C361NC |
30A |
No Fuse |
— |
5.75 |
7.43 |
7.31 |
10.31 |
| • |
• |
C361SC21 |
30A |
30A-250V |
H, K, R |
8.38 |
7.43 |
7.31 |
10.31 |
| • |
• |
C361SC61 |
30A |
60A-250V |
H, K, R |
8.38 |
7.43 |
7.31 |
10.31 |
| • |
• |
C361SC61 |
30A |
30A-600V |
H, J, K, R |
8.38 |
7.43 |
7.31 |
10.31 |
| • |
• |
C361ND |
60A |
No Fuse |
— |
5.75 |
7.43 |
7.31 |
10.31 |
| • |
• |
C361SD22 |
60A |
60A-250V |
H, K, R |
8.38 |
7.43 |
7.31 |
10.31 |
| • |
• |
C361SD22 |
60A |
30A-600V |
J |
8.38 |
7.43 |
7.31 |
10.31 |
| • |
• |
C361SD62 |
60A |
30A-600V |
H, K, R |
8.38 |
7.43 |
7.31 |
10.31 |
| • |
• |
C361SD62 |
60A |
60A-600V |
J |
8.38 |
7.43 |
7.31 |
10.31 |
| • |
• |
C361NE |
100A |
No Fuse |
— |
5.56 |
8.95 |
7.47 |
9.91 |
| • |
• |
C361SE263 |
100A |
100A-250V |
H, K, R |
10.31 |
8.95 |
7.47 |
9.91 |
| • |
• |
C361SE263 |
100A |
100A-600V |
H, K, R |
10.31 |
8.95 |
7.47 |
9.91 |
| • |
• |
C361SE263 |
100A |
100A-600V |
J |
10.31 |
8.95 |
7.47 |
9.91 |
| ¹ , ² |
² |
C361NF |
200A |
No Fuse |
— |
13.06 |
10.00 |
4.94 |
7.94 |
| ¹ , ² |
² |
C361SF264 |
200A |
200A-250V |
H, K, R |
13.06 |
10.00 |
4.94 |
7.94 |
| ¹ , ² |
² |
C361SF264 |
200A |
200A-600V |
H, J, K, R |
13.06 |
10.00 |
4.94 |
7.94 |
¹ Wire bend space "P" does not allow the use of maximum cable size in 8" deep enclosures.
² 200A switch should be installed in enclosures with an "A" dimension of 30" or greater. |
| |
Cutler Hammer C371 Circuit Breaker Operators (C-H Westinghouse Circuit Breakers)
| Fits Enclosure Depth |
Allen Bradley Type No. |
Amp |
|
Space Occupied |
When K=8.62 |
When K=11.62 |
| 8 |
12 |
Rating |
Fuse Type |
L |
M |
P |
P |
| • |
• |
C371E |
150A |
F Frame EHD,FDB,FD,HFD,FDC |
6.00 |
5.50 |
8.44 |
11.44 |
| • |
• |
C371E |
150A |
F Frame HMCP |
6.00 |
5.50 |
8.44 |
11.44 |
|
• |
C371F |
250A |
J Frame JDB,JD,HJD,JDC |
8.94 |
8.00 |
— |
11.25 |
|
• |
C371F |
250A |
J Frame HMCP |
10.94 |
8.00 |
— |
11.25 |
|
• |
C371F |
400A |
K Frame DK,KDB,KD,HKD |
9.75 |
8.00 |
— |
10.75 |
|
• |
C371F |
400A |
K Frame HMCP |
9.75 |
8.00 |
— |
10.75 |
|
• |
C371G |
600A |
L Frame LD,HLD,LDC |
8.44 |
11.88 |
— |
9.18 |
|
• |
C371G |
600A |
L Frame HMCP |
8.44 |
11.88 |
— |
9.18 |
Charts reference Space Occupied by Disconnect Drawing. |
| |
Cutler Hammer Flex-Shaft™ Operator Mechanisms (C-H Westinghouse Circuit Breakers)
| Fits Enclosure Depth |
Complete Operator |
|
Breaker Height |
Breaker Width |
| 8 |
12 |
Mechansim |
Amp Rating |
Fuse Type |
"X" |
"Y" |
| • |
• |
F1S03 |
150A |
F Frame EHD,FDB,FD,HFD,FDC |
6.00 |
4.12 |
| • |
• |
F1S03 |
150A |
F Frame HMCP |
6.00 |
4.12 |
| • |
• |
F2S03 |
250A |
J Frame JDB,JD,HJD,JDC |
10.00 |
4.12 |
| • |
• |
F2S03 |
250A |
J Frame HMCP |
10.00 |
4.12 |
| • |
• |
F3S03 |
400A |
K Frame DK,KDB,KD,HKD |
10.12 |
5.50 |
| • |
• |
F3S03 |
400A |
K Frame HMCP |
12.45 |
5.50 |
|
• |
F4S04 |
600A |
L Frame LD,HLD,LDC |
10.75 |
8.25 |
|
• |
F7S04 |
800A |
M Frame MD,MDS |
16.00 |
8.25 |
|
• |
F5S04 |
1200A |
N Frame ND,HND,NDC |
16.00 |
8.25 |
|
• |
F6S04 |
2500A |
R Frame RD,CRD, RDC |
16.00 |
15.50 |
Part numbers for Complete Operator Mechanisms include flange mounted handle, flexible shaft and circuit breaker mechanism.
The last digit of the part number denotes the shaft length (F1S03=3' length).
- F,J,K frame Flex-Shafts™ available in 3' to 10' lengths.
- L,N,R frame Flex-Shafts™ available in 4' to 6' lengths.
Space Occupied By Disconnect
1. Flex-Shaft™ System permits circuit breaker locations separate from flange mounted handle mechanism.
2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.
3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 4" minimum bending radius for the Flex-Shaft™.
4. Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
- Location "M" from right to left.
Charts reference Space Occupied by Disconnect Drawing.
|
| |
|
General Electric
General Electric Type STDA Disconnect Switches
| Fits Enclosure Depth |
General Electric
Mechanism For
Switch |
Amp
Rating |
|
|
Space Occupied |
When
K=8.62 |
When
K=11.62 |
| 8 |
12 |
Fuse Clip |
Fuse Class |
L |
M |
P |
P |
| • |
• |
TDOM1A |
30A |
No Fuse |
— |
7.75¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1A |
30A |
30A-250V |
H, R |
7.75¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
30A |
30A-600V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
30A |
60A-250V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
30A |
60A-600V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1A |
60A |
No Fuse |
— |
7.75¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
60A |
60A-250V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
60A |
60A-600V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
60A |
100A-250V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
60A |
100A-600V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1A |
100A |
No Fuse |
— |
7.75¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
100A |
100A-250V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
100A |
100A-600V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
100A |
200A-250V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM1B |
100A |
200A-600V |
H, R |
12.38¹ |
5.25 |
9.12 |
12.12 |
| • |
• |
TDOM2 |
200A |
No Fuse |
— |
7.00 |
9.12 |
6.50 |
9.50 |
| • |
• |
TDOM2 |
200A |
200A-250V |
H, R |
15.38 |
9.12 |
6.50 |
9.50 |
| • |
• |
TDOM2 |
200A |
200A-600V |
H, R |
15.38 |
9.12 |
6.50 |
9.50 |
¹ Applies to 8" deep enclosures, and is 0.875" less in 12" deep enclosures. |
|
| |
|
General Electric Type STDA Circuit Breaker Operators
| Fits Enclosure Depth |
General Electric
Mechanism For
Switch |
Amp Rating |
|
Space Occupied |
When
K=8.62 |
When
K=11.62 |
| 8 |
12 |
Fuse Type |
L |
M |
P |
P |
| • |
• |
SDOM1A |
150A |
TEB, TED, THED |
7.75¹ |
5.25 |
9.06 |
12.06 |
| • |
• |
SDOM1A |
150A |
TEC |
7.75¹ |
5.25 |
9.06 |
12.06 |
| • |
• |
TDOM1B |
150A |
TB1 |
12.38¹ |
5.25 |
9.06 |
12.06 |
| • |
• |
TDOM1B |
150A |
TEC, TECL |
12.38¹ |
5.25 |
9.06 |
12.06 |
| • |
• |
TDOM1C |
150A |
TEL |
7.75¹ |
5.25 |
9.06 |
12.06 |
| • |
• |
TDOM1D |
150A |
THLC1 |
7.75¹ |
5.25 |
6.62 |
9.62 |
| • |
• |
TDOM3 |
225A |
TFJ |
10.38 |
5.75 |
7.62 |
10.62 |
| • |
• |
TDOM3 |
225A |
TFK, THFK, TFL |
10.38 |
5.75 |
7.62 |
10.62 |
| • |
• |
TDOM4 |
400A |
TJJ, TJK4, THJK4, TJL4V |
8.25 |
9.38 |
6.69 |
9.69 |
| • |
• |
TDOM4 |
600A |
TJK6, THJK6, TJ4V, TJL4V |
8.25 |
9.38 |
6.69 |
9.69 |
| • |
• |
TDOM5 |
400A |
TB4, TJH6S |
14.25 |
9.38 |
6.69 |
9.69 |
| • |
• |
TDOM6 |
225A |
TLB2, THLC2 |
11.75 |
9.38 |
6.12 |
9.12 |
| • |
• |
TDOM6 |
400A |
TLB4, THLC4 |
11.75 |
9.38 |
4.75 |
7.75 |
| • |
• |
SDOM1A |
150A |
SPECTRA SE150 |
7.75¹ |
5.25 |
9.06 |
12.06 |
| • |
• |
SDOM3 |
250A |
SPECTRA SF250 |
10.38 |
5.75 |
7.06 |
10.06 |
|
• |
SDOM4 |
600A |
SPECTRA SG600 |
10.00 |
7.00 |
— |
7.93 |
¹ Applies to 8" deep enclosures, and is 0.875" less in 12" deep enclosures. Charts reference Space Occupied by Disconnect Drawing. |
|
| |
|
General Electric Circuit Breakers (Spectra-Flex™ Cable Operators)
| Fits Enclosure Depth |
|
|
Circuit Breaker Height |
Circuit Breaker Width |
| C=8 |
C=12 |
Frame Size |
Max Amp Rating |
X |
Y |
| • |
• |
E150 |
150A |
6.31 |
4.12 |
| • |
• |
SE150 |
150A |
6.31 |
4.12 |
|
• |
SF250 |
250A |
10.12 |
4.12 |
|
• |
SG600 |
600A |
10.09 |
5.50 |
|
• |
SK1200 |
1200A |
15.50 |
8.25 |
| Frame Size |
Breaker Mechanism |
Flange Mounting Handle¹ |
Operating Cable² |
| E150 |
SCOM1A |
SCH1 |
SC3L |
| SE150/SF250 |
SCOM1EF |
SCH1 |
SC3L |
| SG600 |
SCOM1G |
SCH1 |
SC3L |
| SK1200 |
SCOM1K |
SCH2K |
SC3H |
¹ Operating Cables are available 3' to 10' lengths. In the table above, the number "3" in the part number indicates a 3' cable.
- GE Spectra-Flex™ Operating Cables permit circuit breaker locations separate from flange mounted handle mechanism.
- See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.
- Select shaft length based on location of circuit breaker in the enclosure. Maintain a 3" minimum bending radius for the Flex-Shaft™.
- Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
- Location "M" from right to left
Charts reference Space Occupied by Disconnect Drawing. |
|
| |
|
Siemens I-T-E
I-T-E - Disconnect Switches (Max-Flex™ Operators)
| Fits Enclosure Depth |
|
Amp
Rating |
|
|
Disconnect Height
"X" |
Disconnect Width
"Y" |
| C=8 |
C=12 |
Switch |
Fuse Clip |
Fuse Class |
| • |
• |
MCS603R |
30A |
No Fuse |
— |
5.52 |
6.13 |
| • |
• |
MCS603R |
30A |
30A-250V |
H,K,R |
8.11 |
6.13 |
| • |
• |
MCS603R |
30A |
30A-600V |
H,K,R |
10.11 |
6.13 |
| • |
• |
MCS603R |
30A |
30A-600V |
J |
8.48 |
6.13 |
| • |
• |
MCS606R |
60A |
No Fuse |
— |
5.52 |
6.13 |
| • |
• |
MCS606R |
60A |
60A-250V |
H,K,R |
7.86 |
6.13 |
| • |
• |
MCS606R |
60A |
60A-600V |
H,K,R |
10.38 |
6.13 |
| • |
• |
MCS606R |
60A |
60A-600V |
J |
8.36 |
6.13 |
| • |
• |
MCS610R |
100A |
No Fuse |
— |
7.59 |
7.38 |
| • |
• |
MCS610R |
100A |
100A-250V |
H,K,R |
11.85 |
7.38 |
| • |
• |
MCS610R |
100A |
100A-600V |
H,K,R |
13.85 |
7.38 |
| • |
• |
MCS610R |
100A |
100A-600V |
J |
10.60 |
7.38 |
| • |
• |
MCS620R |
200A |
No Fuse |
— |
9.00 |
9.17 |
| • |
• |
MCS620R |
200A |
200A-250V |
H,K,R |
14.70 |
9.17 |
| • |
• |
MCS620R |
200A |
200A-600V |
H,K,R |
17.20 |
9.17 |
| • |
• |
MCS620R |
200A |
200A-600V |
J |
13.32 |
9.17 |
|
|
| |
|
Siemens I-T-E Max-Flex™ Operators (Circuit Breakers)
| Complete Operator Mechansim |
|
Breaker
Frame
Size |
Circuit Breaker Type |
Circuit
Breaker Height
"X" |
Circuit Breaker
Width
"Y" |
| Amp Rating |
| FHOE036 |
125A |
ED |
ED2,ED4,ED6,HED4,HED6, |
6.34 |
3.00 |
| FHOE036 |
125A |
CED |
CED6 |
9.58 |
3.00 |
| FHOF036 |
250A |
FD |
FXD6-A,FD6-A,HFD6,FXD6-ETJ,HHFD6, HHFXD6 |
9.50 |
4.50 |
| FHOF036 |
250A |
CFD |
CFD6,CFD6-ETI |
14.25 |
4.50 |
| FHOJ036 |
400A, 600A |
JD, LD |
JXD2,LXD6,JD6,LD6,HJD6,HLD6,HHJD6,HHLD6, HHJXD6,HHLXD6,JXD6-ETI,LXD6-ETI |
11.00 |
7.50 |
| FHOJ036 |
400A, 600A |
CJD,CLD |
CJD6,CLD6,CJD6-ETI,CLD6-ETI |
17.86 |
7.50 |
| FHOLMO36 |
800A |
LMD |
LMD6,LMXD6,HLMD6,HLMDX6,LMXD6-ETI |
16.00 |
9.00 |
Last three digits of operator mechanism part number denote cable length in inches.
- 48" cables are offered for ED,FD,JD/LD operators
Space Occupied By Disconnect
1. I-T-E Max-Flex™ System permits circuit breaker locations separate from flange mounted handle mechanism.
2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.
3. See Siemens I-T-E instructions for disconnect location limitations when using 36" or 48" Max-Flex™ cables.
4. Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
- Location "M" from right to left.
- Charts reference Space Occupied by Disconnect Drawing.
|
|
| |
|
Square D
Square D Class 9422 Disconnect Switches
| Fits Enclosure Depth |
|
Amp
Rating |
|
|
Space Occupied |
When
K=8.62
P |
When
K=11.62
P |
| 8 |
12 |
Square D Type Number |
Fuse Clip |
Fuse Class |
L |
M |
| • |
• |
TCN-30 |
30A |
No Fuse |
— |
3.80 |
6.84 |
7.56 |
10.56 |
| • |
• |
TCF-30 |
30A |
30A-250V |
H, K, R |
5.53 |
6.84 |
7.56 |
10.56 |
| • |
• |
TCF-33 |
30A |
30A-600V |
H, K, R |
8.15 |
6.84 |
7.56 |
10.56 |
| • |
• |
TCF-33 |
30A |
60A-250V |
H, K, R |
6.15 |
6.84 |
7.56 |
10.56 |
| • |
• |
TCF-33 |
30A |
30A-600V |
J |
5.53 |
6.84 |
7.56 |
10.56 |
| • |
• |
TDN-60 |
60A |
No Fuse |
— |
3.80 |
6.84 |
7.56 |
10.56 |
| • |
• |
TDF-60 |
60A |
30A-600V |
H, K, R |
8.15 |
6.84 |
7.56 |
10.56 |
| • |
• |
TDF-60 |
60A |
60A-250V |
H, K, R |
6.15 |
6.84 |
7.56 |
10.56 |
| • |
• |
TDF-63 |
60A |
60A-600V |
H, K, R |
8.65 |
6.84 |
7.56 |
10.56 |
| • |
• |
TDF-63 |
60A |
60A-600V |
J |
5.53 |
6.84 |
7.56 |
10.56 |
|
• |
TEN-10 |
100A |
No Fuse |
— |
3.80 |
6.84 |
7.44 |
10.44 |
|
• |
TEF-10 |
100A |
100A-250V |
H, K, R |
8.25 |
6.84 |
7.44 |
10.44 |
|
• |
TEF-10 |
100A |
100A-600V |
H, K, R |
10.25 |
6.84 |
7.44 |
10.44 |
|
• |
TEF-10 |
100A |
100A-600V |
J |
7.05 |
6.84 |
7.44 |
10.44 |
| • |
• |
TC-1 |
30A |
No Fuse |
— |
5.75 |
6.00 |
6.62 |
9.62 |
| • |
• |
TC-2 |
30A |
30A-250V |
H, K, R |
5.75 |
6.00 |
6.62 |
9.62 |
| • |
• |
TC-3 |
30A |
30A-600V |
H, K, R |
7.75 |
6.00 |
6.62 |
9.62 |
| • |
• |
TC-3 |
30A |
60A-250V |
H, K, R |
5.88 |
6.00 |
6.62 |
9.62 |
| • |
• |
TC-3 |
30A |
30A-600V |
J |
5.75 |
6.00 |
6.62 |
9.62 |
| • |
• |
TD-1 |
60A |
No Fuse |
— |
6.38 |
6.62 |
7.50 |
10.50 |
| • |
• |
TD-2 |
60A |
30A-600V |
H, K, R |
8.50 |
6.62 |
7.50 |
10.50 |
| • |
• |
TD-2 |
60A |
60A-250V |
H, K, R |
6.50 |
6.62 |
7.50 |
10.50 |
| • |
• |
TD-3 |
60A |
60A-600V |
H, K, R |
9.00 |
6.62 |
7.50 |
10.50 |
| • |
• |
TD-3 |
60A |
60A-600V |
J |
6.38 |
6.62 |
7.50 |
10.50 |
|
• |
TE-1 |
100A |
No Fuse |
— |
4.75 |
8.38 |
— |
10.25 |
|
• |
TE-2 |
100A |
100A-250V |
H, K, R |
7.50 |
8.38 |
— |
10.25 |
|
• |
TE-2 |
100A |
100A-600V |
H, K, R |
9.50 |
8.38 |
— |
10.25 |
|
• |
TE-2 |
100A |
100A-600V |
J |
6.25 |
8.38 |
— |
10.25 |
|
• |
TE-3 |
100A |
200A-600V |
J |
13.75 |
8.38 |
— |
10.25 |
|
• |
TF-1 |
200A |
No Fuse |
— |
5.50 |
11.62 |
— |
8.88 |
|
• |
TF-2 |
200A |
200A-250V |
H, K, R |
11.50 |
11.62 |
— |
8.88 |
|
• |
TF-2 |
200A |
200A-600V |
H, K, R |
14.00 |
11.62 |
— |
8.88 |
|
• |
TF-2 |
200A |
200A-600V |
J |
10.12 |
11.62 |
— |
8.88 |
|
• |
TF-3 |
200A |
400A-600V |
J |
14.50 |
11.62 |
— |
8.88 |
|
|
Square D Class 9422 Variable Depth Operators (Circuit Breakers)
| Fits Enclosure Depth |
General Electric
Mechanism For
Switch |
Amp
Rating |
|
Space Occupied |
When
K=8.62
P |
When
K=11.62
P |
| 8 |
12 |
Frame Size |
L |
M |
| • |
• |
RG-1 |
75A |
GJL |
3.53 |
3.74 |
7.47 |
10.47 |
| • |
• |
RG-1 |
100A |
GJL |
3.53 |
3.74 |
7.47 |
10.47 |
| • |
• |
RN-1 |
100A |
FAL,FHL |
5.12 |
5.25 |
7.62 |
10.62 |
| • |
• |
RP-1 |
250A |
KAL,KHL |
7.12 |
5.62 |
8.38 |
11.38 |
|
• |
RR-1 |
400A |
LAL, LHL, Q4L |
7.62 |
8.75 |
— |
7.00 |
Charts reference Space Occupied by Disconnect Drawing. |
|
| |
|
Square D Class 9422 Disconnect Switches (Cable Mechanism 9422-CFT30 and 9422A-1 Handle Mechanism)
| Fits Enclosure Depth |
Square D Type
Number |
Amp
Rating |
|
|
Disconnect Height
"X" |
Disconnect Width
"Y" |
| C=8 |
C=12 |
Fuse Clip |
Fuse Class |
| • |
• |
TCN-30 |
30A |
No Fuse |
— |
5.90 |
6.20 |
| • |
• |
TCF-30 |
30A |
30A-250V |
H, K, R |
7.50 |
6.20 |
| • |
• |
TCF-33 |
30A |
30A-600V |
H, K, R |
10.15 |
6.20 |
| • |
• |
TCF-33 |
30A |
60A-250V |
H, K, R |
8.15 |
6.20 |
| • |
• |
TCF-33 |
30A |
30A-600V |
J |
7.50 |
6.20 |
| • |
• |
TDN-60 |
60A |
No Fuse |
— |
5.90 |
6.20 |
| • |
• |
TDF-60 |
60A |
30A-600V |
H, K, R |
10.15 |
6.20 |
| • |
• |
TDF-60 |
60A |
60A-250V |
H, K, R |
8.15 |
6.20 |
| • |
• |
TDF-63 |
60A |
60A-600V |
H, K, R |
10.65 |
6.20 |
| • |
• |
TDF-63 |
60A |
60A-600V |
J |
7.50 |
6.20 |
|
• |
TEN-10 |
100A |
No Fuse |
— |
5.90 |
6.20 |
|
• |
TEF-10 |
100A |
100A-250V |
H, K, R |
10.35 |
6.20 |
|
• |
TEF-10 |
100A |
100A-600V |
H, K, R |
12.35 |
6.20 |
|
• |
TEF-10 |
100A |
100A-600V |
J |
10.35 |
6.20 |
|
|
| |
|
Square D Class 9422 Cable Mechanism (Circuit Breakers)
| Fits Enclosure Depth |
|
Amp |
|
Circuit Breaker |
Circuit Breaker |
| C=8 |
C=12 |
Cable Type Switch |
Rating |
Frame Type |
Height "X" |
Width "Y" |
| • |
• |
9422 CGJ30 |
75A |
GJL |
4.75 |
3.50 |
| • |
• |
9422 CEJ30 |
100A |
GJL |
4.75 |
3.50 |
| • |
• |
9422 CFA30 |
100A |
FAL,FHL |
6.00 |
4.50 |
| • |
• |
9422 CKA30 |
250A |
KAL,KHL |
8.00 |
4.50 |
|
• |
9422 CLA30 |
400A |
LAL,LHL,Q4L |
11.00 |
6.00 |
Use cable mechanism with circuit breaker and 9422-A1 handle mechanism
Cable operators are offered in 3’, 5’, and 10’ lengths. Last 2 digits of part numbers above (30) are for 3’ cables
Space Occupied By Disconnect Switch
1. Square D Cable System permits circuit breaker locations separate from flange mounted handle mechanism.
2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref "P") needed for line side conductors.
3. Select cable mechanism length based on disconnect location in enclosure. See Square D instructions for minimum cable bend radius.
4. Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
Charts reference Space Occupied by Disconnect Drawing. |
|
| |
|
|